If you have ever attempted to load a SDS-PAGE gel only to miss the well, stab the divider, and then watch helplessly as your sample squirts off into the wrong well, then this tip is for you.

The fortunate among us are able to use pre-cast gels with the wells outlined on the gel plate, but home-made gels don’t have this feature. I’ve seen labs with various loading guides printed off on acetate that they stick to the front plate of the gel before loading, which is better than nothing, but only shows you where the well is supposed to be, not where it is. It is true that after loading enough gels you start to develop an eye for finding the wells, but there is an easier way.

The trick is as simple as this: add a bit of bromophenol blue to your stacking gel. If you remember, bromophenol blue is already in your loading dye, so you aren’t adding anything new to the SDS-PAGE equation. I find that adding the dye to 0.003% is enough to color the stacker, but you can adjust the concentration to your liking. To make things even easier, I simply add the dye to my 4X Stacking Gel Buffer (0.5M Tris-HCl pH 6.8, in my case) to a final concentration of 0.012%. Now you don’t even have to add a new line to your recipe. You can see the results below.

 

Before loading the samples

Before loading the samples (Yes, I know these are ugly wells.)

Samples Loaded

Samples Loaded…

20 minutes into the run

…a third of the way into the run…

After an hour, close to the end of the run

…and close to the end of the run.

As you can see, the wells are easy to visualize. Once the voltage is applied, all the dye in the gel collapses down into the dye front and the gel runs normally. If the color of the stacking gel is too similar to the color of your protein samples, then you can simply add more bromophenol blue to your concentrated loading buffer (you’ll find that recipes vary on this point anyway). For the sake of the photographs, I ran this gel without the cover – this is potentially dangerous, so don’t try this at home…urr… I mean, your lab.

Share this to your network:

16 Comments

  1. Tenzin Gocha on April 1, 2010 at 6:15 am

    I have been using some precast commercial gels lately and i get a lot of leaky wells. Is there a technique or trick in checking if the wells are leaking .
    Thank you in advance

  2. John on March 24, 2010 at 9:46 pm

    Weird. I was thinking about this earlier this week.

    I just tried an alternative way of doing this: Remove the comb and fill the wells with diluted loading buffer (until it’s transparent blue), sit for a minute or so, then wash the wells out with water.

    The residual loading buffer outlines the wells pretty clearly.

    Just an idea for those that don’t want to add it to their stacking gel. 🙂

    Thanks for the article Jode!

  3. Pavan on March 24, 2010 at 10:44 am

    Cool idea Jode! I love Bitesize Bio for all the creative suggestions 🙂

    @Yannick v.G- I frequently make stock solution for stacking and resolving gel having SDS, Acrylamide and buffer and store at 4 degrees. APS and TEMED is added later. I have not seen any problems so far by using up to 1 month old stock solutions. I hope it help.

  4. Sarah on March 23, 2010 at 4:45 pm

    Argh! By Pyrogen, I mean pyronin-G, apologies.

  5. Sarah on March 23, 2010 at 4:41 pm

    Pyrogen G in the stacking gel works nicely as well – and you get a pretty blue and pink effect.