Wide eyed and wet behind the ears, the rookie researcher steps into the lab for the first time. Armed with several years’ knowledge mined from text books, lectures and undergrad labs he feels ready to take his place amongst the worldwide legions of scientists who battle daily in the pursuit of knowledge. Little does he suspect the pitfalls that lie ahead, the classic mistakes and unknown dangers lie in his path.

Here are four rookie researcher disasters. All are true stories that I have witnessed (and one that I made myself – I’ll let you guess which). Each of you will likely have your own tales to tell, please share them in the comments section below and let this serve as a guide, helping rookie researchers of the future avoid the mistakes of others.

1. Pipette inferno. A pristine set of micro-pipettes hang in their holders above the bench. Tools of precision, and of considerable value. Filled with anticipation, the rookie is performing his first ever culture inoculation. Rightfully mindful of the importance of sterile technique he ignites his bunsen burner and begins the procedure, not yet noticing the smell of burning plastic beginning to permeate the air.

The rookie’s nose twitches, becoming aware of the scent. As the realization crystalizes in his mind, he lunges with growing horror to turn the gas tap off. But it’s too late. An unfortunate positioning of the bunsen burner under his pipettes was his undoing. His pristine micro-pipettes are no longer tools of precision or of considerable value but are now deformed icicles of plastic dripping onto the bench. His first report to his supervisor will not be a pleasant one.

2. Exploding agar. In war zones of the world, an exploding bomb of molten agar and glass would be considered a useful tool. In the confines of a laboratory, I would suggest they be avoided at all costs. This advice comes from bitter experience of being in the lab while a young friend of mine, while dutifully performing his technician duties, proceeded to make up a medium-agar solution in an ordinary (non-toughened) glass bottle. After autoclaving, the lid was tightened and the bottle placed on the shelf for future use, the bomb was primed.

One sunny day, he took the glass bottle and, as per protocol, used the microwave to melt the agar. Crucially however he forgot to loosen the lid and the resulting build-up of pressure caused the unsuitably fragile bottle to shatter, forcing open the door of the (cheap) microwave and spraying glass and molten agar around a 2 metre arc. Amazingly, despite the lab being half full, no-one was caught in the blast zone. This was especially lucky as the microwave was on a shelf at head height – molten agar and glass facial, anyone?

3. Culture flask massacre. An orbital shaker is not the place you would normally expect tragedy to occur. However, a communal orbital shaker using sticky stuff to hold the culture flasks in place… and a rookie with a heavy, over-filled 1 litre glass culture flask raises the potential for tragedy tremendously. The shaker was packed with flasks nurturing precious cultures from a number of different labs. Our rookie, puffed with the excitement of growing his first scaled-up culture of his first ever isolated clone strides toward the shaker, pushes the stop button, opens the door and places his flask onto the sticky stuff, making sure it is well stuck down.

The problem with that sticky stuff is that you can never be sure that anything is well stuck down, especially a heavy, overfilled flask and as the rookie left the room his flask was already working it’s way free of it’s anchor. Within minutes his flask had tipped over and his precious culture, which had once held so much promise, was ruined.

The other problem with that sticky stuff is that it loses its stickiness when it gets wet. As his culture medium poured across the shaker platform, it tragically loosened of all of the other culture flasks, condemning them to the doom that lay beneath and ruining the hard work of their owners. One mistake, 30 ruined experiments, 10 angry people.

4. Centrifuge destruction. Few single pieces ordinary lab equipment are more expensive, or more open to damage by those inexperienced in their use, than ultra-centrifuges. The big ones I mean. Confucius (or was it Yoda?) once said “Tubes in rotor spinning at 12,000 x g cannot be balanced by eye alone”. Unfortunately, a PhD rookie I once knew was not party to this undoubted wisdom. Happy that each of her glass centrifuge tubes were filled to “around the same level”, she cranked the machine up to 12,000 x g and went to have a relaxing coffee during the 30 minutes that the machine would do it’s job.

The machine did it’s job, dutifully forcing it’s motor toward the desired 12,000 x g. As the rotor speed increased, the destabilizing effect of the difference between the volumed in the tube became more and more significant. Normally these machines detect imbalances and stop before too much damage is done. For some reason, fate? murphy’s law? or maybe just that it was an old model?, the machine in question did not possess this ability and kept cranking up the revs until the force bent the axle, causing the rotor to destroy the inner drum of the centrifuge, creating a terrifying noise that alerted her lab colleagues to turn the machine off. Returning from her coffee break to continue her experiment, our PhD rookie was horrified by the sight that greeted her. The Force was obviously not strong in her.

Please save future rookies from fates such as these – remember to add your own tales of disaster in a comment below.

Photo: Sea Turtle

Share this to your network:

31 Comments

  1. Sean Mury on June 29, 2010 at 8:35 pm

    Was helping my PI with a grant and was miniprepping 12 different clones to prepare for sequencing. Was in a time crunch and only labeled the top of the tubes. We had an old centrifuge with just a plastic friction cover for the rotor. When I was on my last spin, eluting from the silica columns, the rotor cover came off and chewed every single top off the eppendorfs. I was left with 12 unlabeled minipreps and an irate PI. Needless to say I make sure to label the tops and sides of tubes and to only use centrifuges with a secure rotor cover!

    • Aurora on May 31, 2016 at 2:25 am

      I know I’m replying to this years later, but the exact same thing happened to me a few months ago! Glad to know I’m not the only one. Luckily our lab has a new centrifuge now with a more secure cover.

      • Michelle on April 20, 2018 at 11:54 am

        This happened to me this week! The rotor cover was a screw on (thought it was on ok but may not have been tight) and now destroyed, thread is completely gone, damaged the rotor and potentially have bent the drive shaft. I was mortified as it wasn’t making any weird noises so I walked away and left it for 7mins. Lucky it didn’t set on fire, there was black plastic fragments everywhere :/

        • Pjo on September 30, 2019 at 3:19 pm

          I also once removed the caps of my eppendorf tubes by accident and of course had only labelled the caps…spent 1 hour to piece the right cap back to the tube by fitting the ends together so I wouldn’t waste months of painful work of acquiring RNA 😀

  2. Todd O'Buckley on June 24, 2010 at 6:26 pm

    Similar to @Kerrie’s story, I once switched the UV light on in a biosafety cabinet while making up media to feed cells. The room lights were bright enough that I didn’t notice the color of the light in the hood. When I finished, it took me a minute to figure out where the sunburn on my arms had come from…

  3. Kerrie Pierce on June 2, 2010 at 3:41 pm

    I think I have seen variations of all of the above over the years. One good one was by a very NOT rookie group leader (always a mistake when they try to get back on the horse after too much time at the desk)who cut out his DNA bands from his agarose gel on a UV transilluminator without a face mask. Luckily he wore glasses….he could pretend it was a ski tan.

  4. Mitch on April 12, 2010 at 8:26 pm

    I have three stories:

    1. In the first months of my first job I destroyed a bench-top centrifuge by turning it on 12K RPM w/o the internal lid. One of the microfuge tubes’ tops popped open and I heard the most horrifying noise as the lid bent up in the middle. I was sitting right in front of it and nearly had a heart attack.

    2. A lab mate of mine nearly blew a hole in his arm as he was turning on a mini compressed gas tank w/o a regulator. He had it hooked up to a thick rubber hose and a glass headspace vial – luckilly for him the tube ripped open and not the glass vial. His arm had a foot-long welt on it for a week.

    3. An intern at our company reused a disposable filter and the wrong vessel when she made some media for us. I don’t know exactly how it happened but she ended up contaminating $30,000 worth of bioractor material by trying to save $17 in filters.

  5. Evelyn on December 8, 2009 at 10:16 pm

    Vacuum Pumps: Make sure you use rated glassware and even better perform vacuuming in a hood. Luckily no one was hurt, but it sure was a cool implossion!